{"id":12332,"date":"2026-06-01T17:08:52","date_gmt":"2026-06-01T09:08:52","guid":{"rendered":"https:\/\/shevenmed.com\/?p=12332"},"modified":"2026-06-01T17:08:52","modified_gmt":"2026-06-01T09:08:52","slug":"absorbable-vs-non-absorbable-suture","status":"publish","type":"post","link":"https:\/\/shevenmed.com\/it\/absorbable-vs-non-absorbable-suture\/","title":{"rendered":"Absorbable vs Non-Absorbable Suture: Complete Guide for Medical Buyers"},"content":{"rendered":"<p><strong>Absorbable vs non-absorbable suture<\/strong> \u2014 understanding the difference is one of the most fundamental decisions in surgical supply procurement. Choose the wrong suture material for a clinical application and the consequences range from premature wound dehiscence to unnecessary patient discomfort during suture removal. This guide covers everything a medical distributor, hospital procurement manager, or surgical supply importer needs to know: how each type works, which materials fall into each category, absorption timelines, clinical applications, and how to evaluate suppliers for bulk orders.<\/p>\n<hr \/>\n<h2>What Is the Difference Between Absorbable and Non-Absorbable Sutures?<\/h2>\n<p>The core distinction is simple: absorbable sutures break down inside the body over time and do not require removal, while non-absorbable sutures remain in tissue permanently or until manually removed.<\/p>\n<table>\n<thead>\n<tr>\n<th><\/th>\n<th>Suture riassorbibili<\/th>\n<th>Suture non riassorbibili<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><strong>Breakdown<\/strong><\/td>\n<td>Degraded by body (hydrolysis or enzymatic)<\/td>\n<td>Remain in tissue indefinitely<\/td>\n<\/tr>\n<tr>\n<td><strong>Removal Required<\/strong><\/td>\n<td>No \u2014 absorbed naturally<\/td>\n<td>Yes (unless used for permanent implant)<\/td>\n<\/tr>\n<tr>\n<td><strong>Tensile Strength<\/strong><\/td>\n<td>Decreases as absorption progresses<\/td>\n<td>Maintained long-term<\/td>\n<\/tr>\n<tr>\n<td><strong>Typical Use<\/strong><\/td>\n<td>Internal tissue, deeper layers, mucosa<\/td>\n<td>Skin closure, cardiovascular, permanent fixation<\/td>\n<\/tr>\n<tr>\n<td><strong>Examples<\/strong><\/td>\n<td>PGA, Polyglactin 910, PDO, Catgut<\/td>\n<td>Silk, Nylon, Polypropylene, Polyester<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<hr \/>\n<h2>Absorbable Sutures \u2014 Types, Materials &amp; Absorption Timelines<\/h2>\n<p>Absorbable sutures are broken down by the body through one of two mechanisms:<\/p>\n<ul>\n<li><strong>Hydrolysis<\/strong> \u2014 water gradually breaks down the polymer chain. Used by all synthetic absorbable sutures (PGA, Polyglactin 910, PDO, Poliglecaprone 25). Highly predictable absorption rate.<\/li>\n<li><strong>Enzymatic degradation<\/strong> \u2014 body enzymes break down natural protein fibers. Used by catgut sutures. Less predictable \u2014 absorption rate varies with patient factors such as infection or inflammation.<\/li>\n<\/ul>\n<h3>1. Polyglycolic Acid (PGA) Suture<\/h3>\n<p>PGA is a braided synthetic absorbable suture made from polyglycolic acid polymer. It absorbs through hydrolysis over 60\u201390 days, with tensile strength maintained at approximately 65% at 2 weeks and 35% at 3 weeks. The braided construction provides excellent knot security. Widely used in general surgery, GI, and OB\/GYN. Available in violet and undyed.<\/p>\n<p>\u2192 <a href=\"\/it\/portfolio-items\/absorbable-pga-suture-violet-polyglycolic-acid-surgical-suture\/\">View PGA Suture (E20007) specifications<\/a><\/p>\n<h3>2. Polyglactin 910 Suture (Vicryl Equivalent)<\/h3>\n<p>Polyglactin 910 is a coated braided absorbable suture composed of glycolide and L-lactide copolymer. Absorption occurs over 56\u201370 days \u2014 slightly faster than PGA. The coating provides smoother tissue passage than standard PGA. The most widely used absorbable suture globally; commonly known by the brand name Vicryl (Ethicon). Suitable for general closure, ophthalmic surgery, and OB\/GYN. Available in violet and undyed.<\/p>\n<p>\u2192 <a href=\"\/it\/portfolio-items\/polyglactin-910-suture\/\">View Polyglactin 910 Suture (E20008) specifications<\/a><\/p>\n<h3>3. Polydioxanone Suture (PDO\/PDS Equivalent)<\/h3>\n<p>PDO is a monofilament synthetic absorbable suture with the longest absorption timeline of the synthetic group \u2014 approximately 180 days. Tensile strength is maintained at 70% at 2 weeks and 25% at 6 weeks, making it the preferred choice when extended wound support is critical. Used in fascial closure, pediatric cardiovascular surgery, and tendon repair. The monofilament structure provides smooth tissue passage and low bacterial adhesion. Commonly known as PDS (Ethicon).<\/p>\n<p>\u2192 <a href=\"\/it\/portfolio-items\/absorbable-pdo-suture-polydioxanone-surgical-suture\/\">View Polydioxanone Suture (E20009) specifications<\/a><\/p>\n<h3>4. Poliglecaprone 25 Suture (Monocryl Equivalent)<\/h3>\n<p>Poliglecaprone 25 is a monofilament absorbable suture made from glycolide and epsilon-caprolactone copolymer. Absorption occurs over 90\u2013120 days, but tensile strength is lost faster than PDO \u2014 approximately 50\u201360% at 1 week and 20\u201330% at 2 weeks. This rapid early strength loss makes it ideal for subcuticular skin closure where only short-term support is needed and smooth tissue passage is the priority. Commonly known as Monocryl (Ethicon). Available in violet and undyed.<\/p>\n<p>\u2192 <a href=\"\/it\/portfolio-items\/absorbable-suture-poliglecaprone-25-surgical-suture\/\">View Poliglecaprone 25 Suture (E20010) specifications<\/a><\/p>\n<h3>5. Chromic Catgut Suture<\/h3>\n<p>Chromic catgut is a twisted natural absorbable suture made from purified collagen treated with chromium salts to slow enzymatic absorption to 90\u2013120 days. Unlike synthetic absorbables, its absorption rate varies with patient physiology. Widely used in OB\/GYN, oral surgery, and general soft tissue ligation in markets where catgut is the established standard of care. Available in green and tan.<\/p>\n<p>\u2192 <a href=\"\/it\/portfolio-items\/chromic-catgut-suture\/\">View Chromic Catgut Suture (E20005) specifications<\/a><\/p>\n<h3>6. Plain Catgut Suture<\/h3>\n<p>Plain catgut is untreated purified collagen with faster enzymatic absorption at 70\u201390 days. Softer and more pliable than chromic catgut, preferred for oral surgery and superficial mucosa closure where rapid absorption and minimal patient discomfort are the priority.<\/p>\n<p>\u2192 <a href=\"\/it\/portfolio-items\/plain-catgut-suture\/\">View Plain Catgut Suture (E20006) specifications<\/a><\/p>\n<h3>Absorbable Suture Comparison Table<\/h3>\n<table>\n<thead>\n<tr>\n<th>Suture<\/th>\n<th>Structure<\/th>\n<th>Absorption<\/th>\n<th>Strength at 2 Weeks<\/th>\n<th>Sterilizzazione<\/th>\n<th>Best For<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><strong>PGA (E20007)<\/strong><\/td>\n<td>Braided<\/td>\n<td>60\u201390 days<\/td>\n<td>~65%<\/td>\n<td>Ethylene Oxide<\/td>\n<td>General, GI, OB\/GYN<\/td>\n<\/tr>\n<tr>\n<td><strong>Polyglactin 910 (E20008)<\/strong><\/td>\n<td>Braided<\/td>\n<td>56\u201370 days<\/td>\n<td>~75%<\/td>\n<td>Ethylene Oxide<\/td>\n<td>General, ophthalmic, OB\/GYN<\/td>\n<\/tr>\n<tr>\n<td><strong>PDO (E20009)<\/strong><\/td>\n<td>Monofilament<\/td>\n<td>~180 days<\/td>\n<td>~70%<\/td>\n<td>Ethylene Oxide<\/td>\n<td>Fascial, pediatric, tendon<\/td>\n<\/tr>\n<tr>\n<td><strong>Poliglecaprone 25 (E20010)<\/strong><\/td>\n<td>Monofilament<\/td>\n<td>90\u2013120 days<\/td>\n<td>~50\u201360%<\/td>\n<td>Ethylene Oxide<\/td>\n<td>Subcuticular, cosmetic<\/td>\n<\/tr>\n<tr>\n<td><strong>Chromic Catgut (E20005)<\/strong><\/td>\n<td>Twisted<\/td>\n<td>90\u2013120 days<\/td>\n<td>~40%<\/td>\n<td>Gamma Radiation<\/td>\n<td>OB\/GYN, oral<\/td>\n<\/tr>\n<tr>\n<td><strong>Plain Catgut (E20006)<\/strong><\/td>\n<td>Twisted<\/td>\n<td>70\u201390 days<\/td>\n<td>~20\u201330%<\/td>\n<td>Gamma Radiation<\/td>\n<td>Oral, mucosa<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<hr \/>\n<h2>Non-Absorbable Sutures \u2014 Types &amp; Materials<\/h2>\n<p>Non-absorbable sutures are designed to remain in tissue permanently or until removed post-operatively. They maintain tensile strength indefinitely and are used wherever long-term mechanical support is required.<\/p>\n<h3>1. Silk Braided Suture<\/h3>\n<p>Silk is the most widely used natural non-absorbable suture and has been the reference material in surgery for over a century. Despite being classified as non-absorbable, silk does undergo slow protein degradation over years \u2014 it is not truly permanent like synthetic alternatives. Its braided construction provides excellent knot security and soft handling. Available in black and ivory.<\/p>\n<p>\u2192 <a href=\"\/it\/portfolio-items\/silk-braided-suture\/\">View Silk Braided Suture (E20001) specifications<\/a><\/p>\n<h3>2. Polyester Braided Suture (Ethibond Equivalent)<\/h3>\n<p>Polyester is a truly permanent, non-degrading synthetic braided suture with the highest tensile strength of all braided non-absorbables. Unlike silk, polyester does not degrade in tissue \u2014 it retains mechanical integrity indefinitely. The preferred choice for cardiovascular surgery (valve repair, annuloplasty), hernia repair, and orthopedic applications requiring permanent high-tension fixation. Available in green and blue.<\/p>\n<p>\u2192 <a href=\"\/it\/portfolio-items\/polyester-braided-suture\/\">View Polyester Braided Suture (E20002) specifications<\/a><\/p>\n<h3>3. Nylon Monofilament Suture (Ethilon Equivalent)<\/h3>\n<p>Nylon is a synthetic monofilament non-absorbable suture with low tissue drag and minimal bacterial wicking \u2014 the gold standard for skin closure and plastic surgery. While classified as non-absorbable, nylon undergoes slow hydrolysis losing approximately 15\u201320% tensile strength per year. Available in black and blue.<\/p>\n<p>\u2192 <a href=\"\/it\/portfolio-items\/nylon-monofilament-suture\/\">View Nylon Monofilament Suture (E20003) specifications<\/a><\/p>\n<h3>4. Polypropylene Suture (Prolene Equivalent)<\/h3>\n<p>Polypropylene is a completely biologically inert synthetic monofilament suture \u2014 the only truly permanent, non-degrading monofilament. It has the lowest tissue drag of any suture material and excellent elasticity that accommodates post-operative tissue swelling without cutting through vessel walls. The material of choice for vascular anastomosis, cardiovascular surgery, and hernia mesh fixation. Available in blue, USP 6\/0\u20133.<\/p>\n<p>\u2192 <a href=\"\/it\/portfolio-items\/polypropylene-monofilament-suture\/\">View Polypropylene Suture (E20004) specifications<\/a><\/p>\n<h3>Non-Absorbable Suture Comparison Table<\/h3>\n<table>\n<thead>\n<tr>\n<th>Suture<\/th>\n<th>Structure<\/th>\n<th>Truly Permanent<\/th>\n<th>Tissue Drag<\/th>\n<th>Knot Security<\/th>\n<th>Best For<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><strong>Silk (E20001)<\/strong><\/td>\n<td>Braided<\/td>\n<td>Partial (slow degradation)<\/td>\n<td>Moderato<\/td>\n<td>Eccellente<\/td>\n<td>General, cardiovascular, oral<\/td>\n<\/tr>\n<tr>\n<td><strong>Polyester (E20002)<\/strong><\/td>\n<td>Braided<\/td>\n<td>S\u00ec<\/td>\n<td>Moderato<\/td>\n<td>Eccellente<\/td>\n<td>Cardiovascular, hernia, orthopedic<\/td>\n<\/tr>\n<tr>\n<td><strong>Nylon (E20003)<\/strong><\/td>\n<td>Monofilament<\/td>\n<td>Near-permanent<\/td>\n<td>Basso<\/td>\n<td>Good<\/td>\n<td>Skin, plastic, ophthalmic<\/td>\n<\/tr>\n<tr>\n<td><strong>Polypropylene (E20004)<\/strong><\/td>\n<td>Monofilament<\/td>\n<td>Yes \u2014 fully inert<\/td>\n<td>Lowest<\/td>\n<td>Moderato<\/td>\n<td>Cardiovascular, hernia, plastic<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<hr \/>\n<h2>How to Choose: Absorbable or Non-Absorbable?<\/h2>\n<p>The choice between absorbable and non-absorbable sutures depends on three primary factors:<\/p>\n<h3>1. Tissue Type and Healing Rate<\/h3>\n<p>Fast-healing tissues such as oral mucosa and superficial skin can use fast-absorbing sutures (plain catgut, poliglecaprone 25). Slow-healing tissues such as fascia and tendon require extended support \u2014 either a long-absorbing synthetic (PDO) or a non-absorbable suture. Cardiovascular tissue and hernia repairs require permanent support \u2014 non-absorbable only.<\/p>\n<h3>2. Need for Suture Removal<\/h3>\n<p>Where suture removal is difficult or impractical \u2014 pediatric patients, oral cavity, deep internal layers \u2014 absorbable sutures eliminate a follow-up procedure. Where sutures are placed on accessible skin and removal is routine, either type may be used depending on clinical preference.<\/p>\n<h3>3. Infection Risk<\/h3>\n<p>Monofilament sutures (nylon, polypropylene, PDO, poliglecaprone 25) have lower infection risk than braided sutures because their smooth surface does not provide channels for bacterial wicking. In contaminated or infected wounds, monofilament is generally preferred over braided regardless of absorbability.<\/p>\n<h3>Quick Selection Reference<\/h3>\n<table>\n<thead>\n<tr>\n<th>Clinical Scenario<\/th>\n<th>Recommended Suture<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Skin closure (planned removal)<\/td>\n<td>Nylon (E20003) or Polypropylene (E20004)<\/td>\n<\/tr>\n<tr>\n<td>Subcuticular skin closure (no removal)<\/td>\n<td>Poliglecaprone 25 (E20010)<\/td>\n<\/tr>\n<tr>\n<td>General soft tissue \/ GI closure<\/td>\n<td>PGA (E20007) or Polyglactin 910 (E20008)<\/td>\n<\/tr>\n<tr>\n<td>Fascial \/ abdominal wall closure<\/td>\n<td>PDO (E20009) or Polyester (E20002)<\/td>\n<\/tr>\n<tr>\n<td>Cardiovascular \/ vascular anastomosis<\/td>\n<td>Polypropylene (E20004) or Polyester (E20002)<\/td>\n<\/tr>\n<tr>\n<td>OB\/GYN, episiotomy repair<\/td>\n<td>Chromic Catgut (E20005) or Polyglactin 910 (E20008)<\/td>\n<\/tr>\n<tr>\n<td>Oral surgery<\/td>\n<td>Plain Catgut (E20006) or Chromic Catgut (E20005)<\/td>\n<\/tr>\n<tr>\n<td>Pediatric surgery (no removal)<\/td>\n<td>PDO (E20009) or Poliglecaprone 25 (E20010)<\/td>\n<\/tr>\n<tr>\n<td>Hernia mesh fixation<\/td>\n<td>Polypropylene (E20004) or Polyester (E20002)<\/td>\n<\/tr>\n<tr>\n<td>Ophthalmic surgery<\/td>\n<td>Nylon (E20003) or Polyglactin 910 (E20008)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<hr \/>\n<h2>Branded Sutures vs Generic Equivalents: What Buyers Need to Know<\/h2>\n<p>Many buyers are familiar with branded suture names \u2014 Vicryl, PDS, Monocryl, Prolene, Ethibond, Ethilon \u2014 manufactured primarily by Ethicon (Johnson &amp; Johnson). Generic equivalents manufactured in China offer the same polymer chemistry and performance specifications at significantly lower bulk pricing, with CE and ISO 13485 certification for international regulatory compliance.<\/p>\n<table>\n<thead>\n<tr>\n<th>Brand Name<\/th>\n<th>Generic Material<\/th>\n<th>Even Medical Item No<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Vicryl (Ethicon)<\/td>\n<td>Polyglactin 910<\/td>\n<td>E20008<\/td>\n<\/tr>\n<tr>\n<td>PDS II (Ethicon)<\/td>\n<td>Polydioxanone (PDO)<\/td>\n<td>E20009<\/td>\n<\/tr>\n<tr>\n<td>Monocryl (Ethicon)<\/td>\n<td>Poliglecaprone 25<\/td>\n<td>E20010<\/td>\n<\/tr>\n<tr>\n<td>Prolene (Ethicon)<\/td>\n<td>Polipropilene<\/td>\n<td>E20004<\/td>\n<\/tr>\n<tr>\n<td>Ethibond (Ethicon)<\/td>\n<td>Polyester Braided<\/td>\n<td>E20002<\/td>\n<\/tr>\n<tr>\n<td>Ethilon (Ethicon)<\/td>\n<td>Nylon Monofilament<\/td>\n<td>E20003<\/td>\n<\/tr>\n<tr>\n<td>Dexon (Covidien)<\/td>\n<td>Acido poliglicolico (PGA)<\/td>\n<td>E20007<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<hr \/>\n<h2>Procurement Considerations for Medical Distributors<\/h2>\n<h3>Sterilization Documentation<\/h3>\n<p>Confirm whether the suture requires gamma radiation or ethylene oxide (EO) sterilization. Synthetic absorbable sutures (PGA, Polyglactin, PDO, Poliglecaprone) require EO sterilization to avoid thermal degradation. Natural and non-absorbable sutures typically use gamma radiation. Require batch sterility certificates for each shipment.<\/p>\n<h3>Regulatory Compliance<\/h3>\n<p>For EU import: confirm CE marking under EU MDR. For Middle East and Gulf markets: confirm ISO 13485 certification and country-specific registration requirements. For US market: FDA registration. Even Medical supplies CE and ISO 13485 certified sutures across all 10 materials with documentation available for regulatory submissions.<\/p>\n<h3>USP Size Range<\/h3>\n<p>Confirm the full USP size range available from your supplier. Even Medical supplies all suture types in USP 6\/0 through 2 (polypropylene up to 3), covering the full clinical range from fine ophthalmic to heavy general closure sutures.<\/p>\n<h3>OEM and Private Label<\/h3>\n<p>For distributors building their own brand, confirm OEM capabilities including custom box design, needle specification, thread length, and multi-language labeling. Even Medical supports full OEM programs for all suture types.<\/p>\n<hr \/>\n<h2>Frequently Asked Questions<\/h2>\n<h3>Can absorbable sutures be used for skin closure?<\/h3>\n<p>Yes, in specific scenarios. Subcuticular running sutures using poliglecaprone 25 or polyglactin 910 are common in plastic surgery to eliminate suture marks from transcutaneous stitches. For accessible skin where suture removal is routine, non-absorbable nylon or polypropylene is more commonly used.<\/p>\n<h3>How long does it take for absorbable sutures to dissolve?<\/h3>\n<p>It depends on the material. Plain catgut absorbs in 70\u201390 days; PGA and polyglactin 910 in 56\u201390 days; poliglecaprone 25 in 90\u2013120 days; chromic catgut in 90\u2013120 days; and polydioxanone (PDO) in approximately 180 days. Note that tensile strength is lost much earlier than complete absorption \u2014 PDO loses 75% of its strength by 6 weeks even though full absorption takes 6 months.<\/p>\n<h3>Which suture is strongest?<\/h3>\n<p>Among non-absorbables, polyester braided (E20002) has the highest absolute tensile strength. Among absorbables, PDO (E20009) retains strength the longest. Polypropylene (E20004) has the highest strength-to-diameter ratio of any monofilament non-absorbable.<\/p>\n<h3>What is the difference between braided and monofilament sutures?<\/h3>\n<p>Braided sutures consist of multiple filaments twisted or woven together \u2014 providing better knot security and handling but higher bacterial adhesion risk. Monofilament sutures are a single strand \u2014 providing smoother tissue passage, lower infection risk, and better performance in contaminated wounds, but requiring more careful knot technique.<\/p>\n<h3>Are Chinese-made sutures as good as branded ones?<\/h3>\n<p>CE-certified and ISO 13485-certified sutures from Chinese suppliers use the same polymer chemistry as branded equivalents and are subject to the same international quality standards. The certification process validates sterilization, sterility, tensile strength, and absorption performance. Even Medical sutures carry CE marking and ISO 13485 certification with full batch documentation available for import submissions.<\/p>\n<hr \/>\n<h2>View All Surgical Sutures from Even Medical<\/h2>\n<p>Even Medical supplies all 10 suture types \u2014 absorbable and non-absorbable \u2014 with CE and ISO 13485 certification, USP 6\/0\u20132 full range, and OEM options:<\/p>\n<ul>\n<li><a href=\"\/it\/portfolio-items\/absorbable-pga-suture-violet-polyglycolic-acid-surgical-suture\/\">PGA Suture (E20007) \u2014 Dexon equivalent<\/a><\/li>\n<li><a href=\"\/it\/portfolio-items\/polyglactin-910-suture\/\">Polyglactin 910 Suture (E20008) \u2014 Vicryl equivalent<\/a><\/li>\n<li><a href=\"\/it\/portfolio-items\/absorbable-pdo-suture-polydioxanone-surgical-suture\/\">Polydioxanone Suture (E20009) \u2014 PDS equivalent<\/a><\/li>\n<li><a href=\"\/it\/portfolio-items\/absorbable-suture-poliglecaprone-25-surgical-suture\/\">Poliglecaprone 25 Suture (E20010) \u2014 Monocryl equivalent<\/a><\/li>\n<li><a href=\"\/it\/portfolio-items\/chromic-catgut-suture\/\">Chromic Catgut Suture (E20005)<\/a><\/li>\n<li><a href=\"\/it\/portfolio-items\/plain-catgut-suture\/\">Plain Catgut Suture (E20006)<\/a><\/li>\n<li><a href=\"\/it\/portfolio-items\/silk-braided-suture\/\">Silk Braided Suture (E20001)<\/a><\/li>\n<li><a href=\"\/it\/portfolio-items\/polyester-braided-suture\/\">Polyester Braided Suture (E20002) \u2014 Ethibond equivalent<\/a><\/li>\n<li><a href=\"\/it\/portfolio-items\/nylon-monofilament-suture\/\">Nylon Monofilament Suture (E20003) \u2014 Ethilon equivalent<\/a><\/li>\n<li><a href=\"\/it\/portfolio-items\/polypropylene-monofilament-suture\/\">Polypropylene Suture (E20004) \u2014 Prolene equivalent<\/a><\/li>\n<\/ul>","protected":false},"excerpt":{"rendered":"<p>Absorbable vs non-absorbable suture \u2014 understanding the difference is one of the most fundamental decisions in surgical supply procurement. Choose the wrong suture material for a clinical application and the consequences range from premature wound dehiscence to unnecessary patient discomfort during suture removal. This guide covers everything a medical distributor, hospital procurement manager, or surgical supply importer needs to know:  [&#8230;]<\/p>\n","protected":false},"author":1,"featured_media":12336,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[822,829,823,825,826,828,827,292,830,824],"class_list":["post-12332","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-latest-posts","tag-absorbable-suture","tag-medical-buyer-guide","tag-non-absorbable-suture","tag-pga-suture","tag-polyglactin-910","tag-polypropylene-suture","tag-silk-suture","tag-surgical-suture","tag-suture-selection","tag-suture-types"],"_links":{"self":[{"href":"https:\/\/shevenmed.com\/it\/wp-json\/wp\/v2\/posts\/12332","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/shevenmed.com\/it\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/shevenmed.com\/it\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/shevenmed.com\/it\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/shevenmed.com\/it\/wp-json\/wp\/v2\/comments?post=12332"}],"version-history":[{"count":0,"href":"https:\/\/shevenmed.com\/it\/wp-json\/wp\/v2\/posts\/12332\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/shevenmed.com\/it\/wp-json\/wp\/v2\/media\/12336"}],"wp:attachment":[{"href":"https:\/\/shevenmed.com\/it\/wp-json\/wp\/v2\/media?parent=12332"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/shevenmed.com\/it\/wp-json\/wp\/v2\/categories?post=12332"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/shevenmed.com\/it\/wp-json\/wp\/v2\/tags?post=12332"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}